{"title":"High Purity Tubing","description":null,"products":[{"product_id":"tygon-acg00007-1-8-i-d-x-1-4-o-d-x-1-16-wall-formulation-2475-50-package-length-high-purity-tubing","title":"ACG00007 Tygon® by Saint Gobain | 1\/8\" I.D. x 1\/4\" O.D x 1\/16\" Wall | Formulation 2475 | High Purity Tubing | 50' Package Length","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eSPECIFICATIONS\u003c\/p\u003e \n\u003cdiv class=\"table-responsive\"\u003e\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication:\u003c\/th\u003e\n\u003ctd\u003eSterile filling and Dispensing Systems, Diagnostic Equipment,  Nuclear Equipment, Laboratory Analytical Instrumentation,  Infusion Sets for Parenterals and Drugs, Cosmetic Production,  Food and Beverage Processing, Cell and Tissue Culture Transport\u003c\/td\u003e\n\u003cth\u003eSAE Rating:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOther Ratings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eTube:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReinforcement:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eCover:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Range:\u003c\/th\u003e\n\u003ctd\u003e-108 deg. F (-78 deg. C) - 125 deg. F (52 deg. C)\u003c\/td\u003e\n\u003cth\u003eCrimp Fittings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReusable Fittings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eSpecifications\u003c\/th\u003e\n\u003ctd\u003eFDA 21 CFR, USP Class VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLiterature:\u003c\/th\u003e\n\u003ctd colspan=\"3\"\u003e\u003ca href=\"\/http:\/\/emurdock.com\/tygontubing\/Tygon2475.pdf\"\u003eTygon® High Purity Tubing - Formulation 2475 (PDF)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"4\"\u003eOther Features:\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eExceptionally Low Absorption and Adsorption Compared to Silicone\u003c\/li\u003e\n\u003cli\u003eSmooth Inner Surface Inhibits Particulate Entrapment\u003c\/li\u003e\n\u003cli\u003eHighly Resistant to Aggressive Cleaners and Sanitizers\u003c\/li\u003e\n\u003cli\u003ePlasticizer Free\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cb\u003eWARNING: Tygon® High Purity Tubing - Formulation 2475 is not intended as an implant material.\u003c\/b\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"table-responsive\"\u003e\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eInside Diameter (in.)\u003c\/th\u003e\n\u003cth\u003eOutside Diameter (in.)\u003c\/th\u003e\n\u003cth\u003eWall Thickness (in.)\u003c\/th\u003e\n\u003cth\u003eMin. Bend Radius (in.)\u003c\/th\u003e\n\u003cth\u003eMax. Suggested Working Pressure at 180 deg. F (PSI)*\u003c\/th\u003e\n\u003cth\u003eVacuum Rating at 73 deg. F (in. Hg)\u003c\/th\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00003-1-16-I-D-x-3-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00003\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e60 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00007-1-8-I-D-x-1-4-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00007\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e45 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00012-3-16-I-D-x-5-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00012\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e5\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003ctd\u003e35 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00017-1-4-I-D-x-3-8-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00017\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e25 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00022-5-16-I-D-x-7-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00022\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/16\"\u003c\/td\u003e\n\u003ctd\u003e7\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1-3\/8\"\u003c\/td\u003e\n\u003ctd\u003e17 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00027-3-8-I-D-x-1-2-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00027\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1-5\/8\"\u003c\/td\u003e\n\u003ctd\u003e15 PSI\u003c\/td\u003e\n\u003ctd\u003e25.0 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00038-1-2-I-D-x-3-4-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00038\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2\"\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1-7\/8\"\u003c\/td\u003e\n\u003ctd\u003e20 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00046-5-8-I-D-x-7-8-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00046\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003ctd\u003e7\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e2-7\/8\"\u003c\/td\u003e\n\u003ctd\u003e17 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00053-3-4-I-D-x-1-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00053\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e16 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG42064-1-I-D-x-1-3-8-O-D-x-3-16-Wall-Formulation-2475-25-Package-Length-High-Purity-Tubing\"\u003eACG42064\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e1-3\/8\"\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e19 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e25ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e * Working pressures are calculated at a 1:5 ratio relative to burst pressure using ASTM D1599 Note: Every attempt has been taken to provide accurate detailed usable information online, however please consult Saint-Gobain Performance Plastics information documents for the most accurate and up to date data and specifics. \u003cb\u003eImportant!\u003c\/b\u003e It is the user's responsibility to ensure the suitability and safety of Saint-Gobain Performance Plastics tubing for all intended uses. Laboratory and clinical tests must be conducted in accordance with applicable regulatory requirements in order to determine the safety and effectiveness for use of tubing in any particular application. ©2003 Saint-Gobain Performance Plastics Corporation This product is priced and sold by Packaged Length. At this time, this particular hose is not available \"by the foot\" through our site.\u003c\/p\u003e","brand":"Saint-Gobain","offers":[{"title":"Default Title","offer_id":45361535123618,"sku":"ACG00007 Saint Gobain","price":112.23,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0263\/2895\/7003\/files\/2475_1.png?v=1742648539"},{"product_id":"tygon-acg00053-3-4-i-d-x-1-o-d-x-1-8-wall-formulation-2475-50-package-length-high-purity-tubing","title":"ACG00053 Tygon® by Saint Gobain | 3\/4\" I.D. x 1\" O.D x 1\/8\" Wall | Formulation 2475 | High Purity Tubing | 50' Package Length","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eSPECIFICATIONS\u003c\/p\u003e \n\u003cdiv class=\"table-responsive\"\u003e\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication:\u003c\/th\u003e\n\u003ctd\u003eSterile filling and Dispensing Systems, Diagnostic Equipment,  Nuclear Equipment, Laboratory Analytical Instrumentation,  Infusion Sets for Parenterals and Drugs, Cosmetic Production,  Food and Beverage Processing, Cell and Tissue Culture Transport\u003c\/td\u003e\n\u003cth\u003eSAE Rating:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOther Ratings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eTube:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReinforcement:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eCover:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Range:\u003c\/th\u003e\n\u003ctd\u003e-108 deg. F (-78 deg. C) - 125 deg. F (52 deg. C)\u003c\/td\u003e\n\u003cth\u003eCrimp Fittings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReusable Fittings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eSpecifications\u003c\/th\u003e\n\u003ctd\u003eFDA 21 CFR, USP Class VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLiterature:\u003c\/th\u003e\n\u003ctd colspan=\"3\"\u003e\u003ca href=\"\/http:\/\/emurdock.com\/tygontubing\/Tygon2475.pdf\"\u003eTygon® High Purity Tubing - Formulation 2475 (PDF)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"4\"\u003eOther Features:\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eExceptionally Low Absorption and Adsorption Compared to Silicone\u003c\/li\u003e\n\u003cli\u003eSmooth Inner Surface Inhibits Particulate Entrapment\u003c\/li\u003e\n\u003cli\u003eHighly Resistant to Aggressive Cleaners and Sanitizers\u003c\/li\u003e\n\u003cli\u003ePlasticizer Free\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cb\u003eWARNING: Tygon® High Purity Tubing - Formulation 2475 is not intended as an implant material.\u003c\/b\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"table-responsive\"\u003e\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eInside Diameter (in.)\u003c\/th\u003e\n\u003cth\u003eOutside Diameter (in.)\u003c\/th\u003e\n\u003cth\u003eWall Thickness (in.)\u003c\/th\u003e\n\u003cth\u003eMin. Bend Radius (in.)\u003c\/th\u003e\n\u003cth\u003eMax. Suggested Working Pressure at 180 deg. F (PSI)*\u003c\/th\u003e\n\u003cth\u003eVacuum Rating at 73 deg. F (in. Hg)\u003c\/th\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00003-1-16-I-D-x-3-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00003\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e60 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00007-1-8-I-D-x-1-4-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00007\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e45 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00012-3-16-I-D-x-5-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00012\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e5\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003ctd\u003e35 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00017-1-4-I-D-x-3-8-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00017\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e25 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00022-5-16-I-D-x-7-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00022\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/16\"\u003c\/td\u003e\n\u003ctd\u003e7\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1-3\/8\"\u003c\/td\u003e\n\u003ctd\u003e17 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00027-3-8-I-D-x-1-2-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00027\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1-5\/8\"\u003c\/td\u003e\n\u003ctd\u003e15 PSI\u003c\/td\u003e\n\u003ctd\u003e25.0 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00038-1-2-I-D-x-3-4-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00038\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2\"\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1-7\/8\"\u003c\/td\u003e\n\u003ctd\u003e20 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00046-5-8-I-D-x-7-8-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00046\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003ctd\u003e7\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e2-7\/8\"\u003c\/td\u003e\n\u003ctd\u003e17 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00053-3-4-I-D-x-1-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00053\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e16 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG42064-1-I-D-x-1-3-8-O-D-x-3-16-Wall-Formulation-2475-25-Package-Length-High-Purity-Tubing\"\u003eACG42064\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e1-3\/8\"\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e19 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e25ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e * Working pressures are calculated at a 1:5 ratio relative to burst pressure using ASTM D1599 Note: Every attempt has been taken to provide accurate detailed usable information online, however please consult Saint-Gobain Performance Plastics information documents for the most accurate and up to date data and specifics. \u003cb\u003eImportant!\u003c\/b\u003e It is the user's responsibility to ensure the suitability and safety of Saint-Gobain Performance Plastics tubing for all intended uses. Laboratory and clinical tests must be conducted in accordance with applicable regulatory requirements in order to determine the safety and effectiveness for use of tubing in any particular application. ©2003 Saint-Gobain Performance Plastics Corporation This product is priced and sold by Packaged Length. At this time, this particular hose is not available \"by the foot\" through our site.\u003c\/p\u003e","brand":"Saint-Gobain","offers":[{"title":"Default Title","offer_id":45361535647906,"sku":"ACG00053 Saint Gobain","price":449.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0263\/2895\/7003\/files\/2475_8.png?v=1742648535"},{"product_id":"tygon-acg00017-1-4-i-d-x-3-8-o-d-x-1-16-wall-formulation-2475-50-package-length-high-purity-tubing","title":"ACG00017 Tygon® by Saint Gobain | 1\/4\" I.D. x 3\/8\" O.D x 1\/16\" Wall | Formulation 2475 | High Purity Tubing | 50' Package Length","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eSPECIFICATIONS\u003c\/p\u003e \n\u003cdiv class=\"table-responsive\"\u003e\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication:\u003c\/th\u003e\n\u003ctd\u003eSterile filling and Dispensing Systems, Diagnostic Equipment,  Nuclear Equipment, Laboratory Analytical Instrumentation,  Infusion Sets for Parenterals and Drugs, Cosmetic Production,  Food and Beverage Processing, Cell and Tissue Culture Transport\u003c\/td\u003e\n\u003cth\u003eSAE Rating:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOther Ratings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eTube:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReinforcement:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eCover:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Range:\u003c\/th\u003e\n\u003ctd\u003e-108 deg. F (-78 deg. C) - 125 deg. F (52 deg. C)\u003c\/td\u003e\n\u003cth\u003eCrimp Fittings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReusable Fittings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eSpecifications\u003c\/th\u003e\n\u003ctd\u003eFDA 21 CFR, USP Class VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLiterature:\u003c\/th\u003e\n\u003ctd colspan=\"3\"\u003e\u003ca href=\"\/http:\/\/emurdock.com\/tygontubing\/Tygon2475.pdf\"\u003eTygon® High Purity Tubing - Formulation 2475 (PDF)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"4\"\u003eOther Features:\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eExceptionally Low Absorption and Adsorption Compared to Silicone\u003c\/li\u003e\n\u003cli\u003eSmooth Inner Surface Inhibits Particulate Entrapment\u003c\/li\u003e\n\u003cli\u003eHighly Resistant to Aggressive Cleaners and Sanitizers\u003c\/li\u003e\n\u003cli\u003ePlasticizer Free\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cb\u003eWARNING: Tygon® High Purity Tubing - Formulation 2475 is not intended as an implant material.\u003c\/b\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"table-responsive\"\u003e\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eInside Diameter (in.)\u003c\/th\u003e\n\u003cth\u003eOutside Diameter (in.)\u003c\/th\u003e\n\u003cth\u003eWall Thickness (in.)\u003c\/th\u003e\n\u003cth\u003eMin. Bend Radius (in.)\u003c\/th\u003e\n\u003cth\u003eMax. Suggested Working Pressure at 180 deg. F (PSI)*\u003c\/th\u003e\n\u003cth\u003eVacuum Rating at 73 deg. F (in. Hg)\u003c\/th\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00003-1-16-I-D-x-3-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00003\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e60 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00007-1-8-I-D-x-1-4-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00007\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e45 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00012-3-16-I-D-x-5-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00012\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e5\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003ctd\u003e35 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00017-1-4-I-D-x-3-8-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00017\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e25 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00022-5-16-I-D-x-7-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00022\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/16\"\u003c\/td\u003e\n\u003ctd\u003e7\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1-3\/8\"\u003c\/td\u003e\n\u003ctd\u003e17 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00027-3-8-I-D-x-1-2-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00027\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1-5\/8\"\u003c\/td\u003e\n\u003ctd\u003e15 PSI\u003c\/td\u003e\n\u003ctd\u003e25.0 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00038-1-2-I-D-x-3-4-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00038\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2\"\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1-7\/8\"\u003c\/td\u003e\n\u003ctd\u003e20 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00046-5-8-I-D-x-7-8-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00046\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003ctd\u003e7\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e2-7\/8\"\u003c\/td\u003e\n\u003ctd\u003e17 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00053-3-4-I-D-x-1-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00053\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e16 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG42064-1-I-D-x-1-3-8-O-D-x-3-16-Wall-Formulation-2475-25-Package-Length-High-Purity-Tubing\"\u003eACG42064\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e1-3\/8\"\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e19 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e25ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e * Working pressures are calculated at a 1:5 ratio relative to burst pressure using ASTM D1599 Note: Every attempt has been taken to provide accurate detailed usable information online, however please consult Saint-Gobain Performance Plastics information documents for the most accurate and up to date data and specifics. \u003cb\u003eImportant!\u003c\/b\u003e It is the user's responsibility to ensure the suitability and safety of Saint-Gobain Performance Plastics tubing for all intended uses. Laboratory and clinical tests must be conducted in accordance with applicable regulatory requirements in order to determine the safety and effectiveness for use of tubing in any particular application. ©2003 Saint-Gobain Performance Plastics Corporation This product is priced and sold by Packaged Length. At this time, this particular hose is not available \"by the foot\" through our site.\u003c\/p\u003e","brand":"Saint-Gobain","offers":[{"title":"Default Title","offer_id":45361536860322,"sku":"ACG00017 Saint Gobain","price":129.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0263\/2895\/7003\/files\/2475_3.png?v=1742648539"},{"product_id":"tygon-acg00027-3-8-i-d-x-1-2-o-d-x-1-16-wall-formulation-2475-50-package-length-high-purity-tubing","title":"ACG00027 Tygon® by Saint Gobain | 3\/8\" I.D. x 1\/2\" O.D x 1\/16\" Wall | Formulation 2475 | High Purity Tubing | 50' Package Length","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eSPECIFICATIONS\u003c\/p\u003e \n\u003cdiv class=\"table-responsive\"\u003e\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication:\u003c\/th\u003e\n\u003ctd\u003eSterile filling and Dispensing Systems, Diagnostic Equipment,  Nuclear Equipment, Laboratory Analytical Instrumentation,  Infusion Sets for Parenterals and Drugs, Cosmetic Production,  Food and Beverage Processing, Cell and Tissue Culture Transport\u003c\/td\u003e\n\u003cth\u003eSAE Rating:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOther Ratings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eTube:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReinforcement:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eCover:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Range:\u003c\/th\u003e\n\u003ctd\u003e-108 deg. F (-78 deg. C) - 125 deg. F (52 deg. C)\u003c\/td\u003e\n\u003cth\u003eCrimp Fittings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReusable Fittings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eSpecifications\u003c\/th\u003e\n\u003ctd\u003eFDA 21 CFR, USP Class VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLiterature:\u003c\/th\u003e\n\u003ctd colspan=\"3\"\u003e\u003ca href=\"\/http:\/\/emurdock.com\/tygontubing\/Tygon2475.pdf\"\u003eTygon® High Purity Tubing - Formulation 2475 (PDF)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"4\"\u003eOther Features:\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eExceptionally Low Absorption and Adsorption Compared to Silicone\u003c\/li\u003e\n\u003cli\u003eSmooth Inner Surface Inhibits Particulate Entrapment\u003c\/li\u003e\n\u003cli\u003eHighly Resistant to Aggressive Cleaners and Sanitizers\u003c\/li\u003e\n\u003cli\u003ePlasticizer Free\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cb\u003eWARNING: Tygon® High Purity Tubing - Formulation 2475 is not intended as an implant material.\u003c\/b\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"table-responsive\"\u003e\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eInside Diameter (in.)\u003c\/th\u003e\n\u003cth\u003eOutside Diameter (in.)\u003c\/th\u003e\n\u003cth\u003eWall Thickness (in.)\u003c\/th\u003e\n\u003cth\u003eMin. Bend Radius (in.)\u003c\/th\u003e\n\u003cth\u003eMax. Suggested Working Pressure at 180 deg. F (PSI)*\u003c\/th\u003e\n\u003cth\u003eVacuum Rating at 73 deg. F (in. Hg)\u003c\/th\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00003-1-16-I-D-x-3-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00003\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e60 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00007-1-8-I-D-x-1-4-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00007\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e45 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00012-3-16-I-D-x-5-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00012\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e5\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003ctd\u003e35 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00017-1-4-I-D-x-3-8-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00017\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e25 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00022-5-16-I-D-x-7-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00022\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/16\"\u003c\/td\u003e\n\u003ctd\u003e7\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1-3\/8\"\u003c\/td\u003e\n\u003ctd\u003e17 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00027-3-8-I-D-x-1-2-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00027\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1-5\/8\"\u003c\/td\u003e\n\u003ctd\u003e15 PSI\u003c\/td\u003e\n\u003ctd\u003e25.0 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00038-1-2-I-D-x-3-4-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00038\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2\"\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1-7\/8\"\u003c\/td\u003e\n\u003ctd\u003e20 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00046-5-8-I-D-x-7-8-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00046\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003ctd\u003e7\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e2-7\/8\"\u003c\/td\u003e\n\u003ctd\u003e17 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00053-3-4-I-D-x-1-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00053\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e16 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG42064-1-I-D-x-1-3-8-O-D-x-3-16-Wall-Formulation-2475-25-Package-Length-High-Purity-Tubing\"\u003eACG42064\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e1-3\/8\"\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e19 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e25ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e * Working pressures are calculated at a 1:5 ratio relative to burst pressure using ASTM D1599 Note: Every attempt has been taken to provide accurate detailed usable information online, however please consult Saint-Gobain Performance Plastics information documents for the most accurate and up to date data and specifics. \u003cb\u003eImportant!\u003c\/b\u003e It is the user's responsibility to ensure the suitability and safety of Saint-Gobain Performance Plastics tubing for all intended uses. Laboratory and clinical tests must be conducted in accordance with applicable regulatory requirements in order to determine the safety and effectiveness for use of tubing in any particular application. ©2003 Saint-Gobain Performance Plastics Corporation This product is priced and sold by Packaged Length. At this time, this particular hose is not available \"by the foot\" through our site.\u003c\/p\u003e","brand":"Saint-Gobain","offers":[{"title":"Default Title","offer_id":45361536893090,"sku":"ACG00027 Saint Gobain","price":165.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0263\/2895\/7003\/files\/2475_5.png?v=1742648553"},{"product_id":"tygon-acg00012-3-16-i-d-x-5-16-o-d-x-1-16-wall-formulation-2475-50-package-length-high-purity-tubing","title":"ACG00012 Tygon® by Saint Gobain | 3\/16\" I.D. x 5\/16\" O.D x 1\/16\" Wall | Formulation 2475 | High Purity Tubing | 50' Package Length","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eSPECIFICATIONS\u003c\/p\u003e \n\u003cdiv class=\"table-responsive\"\u003e\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication:\u003c\/th\u003e\n\u003ctd\u003eSterile filling and Dispensing Systems, Diagnostic Equipment,  Nuclear Equipment, Laboratory Analytical Instrumentation,  Infusion Sets for Parenterals and Drugs, Cosmetic Production,  Food and Beverage Processing, Cell and Tissue Culture Transport\u003c\/td\u003e\n\u003cth\u003eSAE Rating:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOther Ratings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eTube:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReinforcement:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eCover:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Range:\u003c\/th\u003e\n\u003ctd\u003e-108 deg. F (-78 deg. C) - 125 deg. F (52 deg. C)\u003c\/td\u003e\n\u003cth\u003eCrimp Fittings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReusable Fittings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eSpecifications\u003c\/th\u003e\n\u003ctd\u003eFDA 21 CFR, USP Class VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLiterature:\u003c\/th\u003e\n\u003ctd colspan=\"3\"\u003e\u003ca href=\"\/http:\/\/emurdock.com\/tygontubing\/Tygon2475.pdf\"\u003eTygon® High Purity Tubing - Formulation 2475 (PDF)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"4\"\u003eOther Features:\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eExceptionally Low Absorption and Adsorption Compared to Silicone\u003c\/li\u003e\n\u003cli\u003eSmooth Inner Surface Inhibits Particulate Entrapment\u003c\/li\u003e\n\u003cli\u003eHighly Resistant to Aggressive Cleaners and Sanitizers\u003c\/li\u003e\n\u003cli\u003ePlasticizer Free\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cb\u003eWARNING: Tygon® High Purity Tubing - Formulation 2475 is not intended as an implant material.\u003c\/b\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"table-responsive\"\u003e\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eInside Diameter (in.)\u003c\/th\u003e\n\u003cth\u003eOutside Diameter (in.)\u003c\/th\u003e\n\u003cth\u003eWall Thickness (in.)\u003c\/th\u003e\n\u003cth\u003eMin. Bend Radius (in.)\u003c\/th\u003e\n\u003cth\u003eMax. Suggested Working Pressure at 180 deg. F (PSI)*\u003c\/th\u003e\n\u003cth\u003eVacuum Rating at 73 deg. F (in. Hg)\u003c\/th\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00003-1-16-I-D-x-3-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00003\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e60 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00007-1-8-I-D-x-1-4-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00007\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e45 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00012-3-16-I-D-x-5-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00012\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e5\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003ctd\u003e35 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00017-1-4-I-D-x-3-8-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00017\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e25 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00022-5-16-I-D-x-7-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00022\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/16\"\u003c\/td\u003e\n\u003ctd\u003e7\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1-3\/8\"\u003c\/td\u003e\n\u003ctd\u003e17 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00027-3-8-I-D-x-1-2-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00027\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1-5\/8\"\u003c\/td\u003e\n\u003ctd\u003e15 PSI\u003c\/td\u003e\n\u003ctd\u003e25.0 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00038-1-2-I-D-x-3-4-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00038\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2\"\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1-7\/8\"\u003c\/td\u003e\n\u003ctd\u003e20 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00046-5-8-I-D-x-7-8-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00046\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003ctd\u003e7\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e2-7\/8\"\u003c\/td\u003e\n\u003ctd\u003e17 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00053-3-4-I-D-x-1-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00053\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e16 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG42064-1-I-D-x-1-3-8-O-D-x-3-16-Wall-Formulation-2475-25-Package-Length-High-Purity-Tubing\"\u003eACG42064\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e1-3\/8\"\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e19 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e25ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e * Working pressures are calculated at a 1:5 ratio relative to burst pressure using ASTM D1599 Note: Every attempt has been taken to provide accurate detailed usable information online, however please consult Saint-Gobain Performance Plastics information documents for the most accurate and up to date data and specifics. \u003cb\u003eImportant!\u003c\/b\u003e It is the user's responsibility to ensure the suitability and safety of Saint-Gobain Performance Plastics tubing for all intended uses. Laboratory and clinical tests must be conducted in accordance with applicable regulatory requirements in order to determine the safety and effectiveness for use of tubing in any particular application. ©2003 Saint-Gobain Performance Plastics Corporation This product is priced and sold by Packaged Length. At this time, this particular hose is not available \"by the foot\" through our site.\u003c\/p\u003e","brand":"Saint-Gobain","offers":[{"title":"Default Title","offer_id":45361538629794,"sku":"ACG00012 Saint Gobain","price":120.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0263\/2895\/7003\/files\/2475_2.png?v=1742648538"},{"product_id":"tygon-acg42064-1-i-d-x-1-3-8-o-d-x-3-16-wall-formulation-2475-25-package-length-high-purity-tubing","title":"ACG42064 Tygon® by Saint Gobain | 1\" I.D. x 1-3\/8\" O.D x 3\/16\" Wall | Formulation 2475 | High Purity Tubing | 25' Package Length","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eSPECIFICATIONS\u003c\/p\u003e \n\u003cdiv class=\"table-responsive\"\u003e\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication:\u003c\/th\u003e\n\u003ctd\u003eSterile filling and Dispensing Systems, Diagnostic Equipment,  Nuclear Equipment, Laboratory Analytical Instrumentation,  Infusion Sets for Parenterals and Drugs, Cosmetic Production,  Food and Beverage Processing, Cell and Tissue Culture Transport\u003c\/td\u003e\n\u003cth\u003eSAE Rating:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOther Ratings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eTube:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReinforcement:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eCover:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Range:\u003c\/th\u003e\n\u003ctd\u003e-108 deg. F (-78 deg. C) - 125 deg. F (52 deg. C)\u003c\/td\u003e\n\u003cth\u003eCrimp Fittings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReusable Fittings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eSpecifications\u003c\/th\u003e\n\u003ctd\u003eFDA 21 CFR, USP Class VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLiterature:\u003c\/th\u003e\n\u003ctd colspan=\"3\"\u003e\u003ca href=\"\/http:\/\/emurdock.com\/tygontubing\/Tygon2475.pdf\"\u003eTygon® High Purity Tubing - Formulation 2475 (PDF)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"4\"\u003eOther Features:\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eExceptionally Low Absorption and Adsorption Compared to Silicone\u003c\/li\u003e\n\u003cli\u003eSmooth Inner Surface Inhibits Particulate Entrapment\u003c\/li\u003e\n\u003cli\u003eHighly Resistant to Aggressive Cleaners and Sanitizers\u003c\/li\u003e\n\u003cli\u003ePlasticizer Free\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cb\u003eWARNING: Tygon® High Purity Tubing - Formulation 2475 is not intended as an implant material.\u003c\/b\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-responsive\"\u003e\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eInside Diameter (in.)\u003c\/th\u003e\n\u003cth\u003eOutside Diameter (in.)\u003c\/th\u003e\n\u003cth\u003eWall Thickness (in.)\u003c\/th\u003e\n\u003cth\u003eMin. Bend Radius (in.)\u003c\/th\u003e\n\u003cth\u003eMax. Suggested Working Pressure at 180 deg. F (PSI)*\u003c\/th\u003e\n\u003cth\u003eVacuum Rating at 73 deg. F (in. Hg)\u003c\/th\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00003-1-16-I-D-x-3-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00003\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e60 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00007-1-8-I-D-x-1-4-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00007\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e45 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00012-3-16-I-D-x-5-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00012\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e5\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003ctd\u003e35 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00017-1-4-I-D-x-3-8-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00017\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e25 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00022-5-16-I-D-x-7-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00022\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/16\"\u003c\/td\u003e\n\u003ctd\u003e7\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1-3\/8\"\u003c\/td\u003e\n\u003ctd\u003e17 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00027-3-8-I-D-x-1-2-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00027\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1-5\/8\"\u003c\/td\u003e\n\u003ctd\u003e15 PSI\u003c\/td\u003e\n\u003ctd\u003e25.0 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00038-1-2-I-D-x-3-4-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00038\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2\"\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1-7\/8\"\u003c\/td\u003e\n\u003ctd\u003e20 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00046-5-8-I-D-x-7-8-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00046\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003ctd\u003e7\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e2-7\/8\"\u003c\/td\u003e\n\u003ctd\u003e17 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00053-3-4-I-D-x-1-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00053\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e16 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG42064-1-I-D-x-1-3-8-O-D-x-3-16-Wall-Formulation-2475-25-Package-Length-High-Purity-Tubing\"\u003eACG42064\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e1-3\/8\"\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e19 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e25ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e * Working pressures are calculated at a 1:5 ratio relative to burst pressure using ASTM D1599 Note: Every attempt has been taken to provide accurate detailed usable information online, however please consult Saint-Gobain Performance Plastics information documents for the most accurate and up to date data and specifics. \u003cb\u003eImportant!\u003c\/b\u003e It is the user's responsibility to ensure the suitability and safety of Saint-Gobain Performance Plastics tubing for all intended uses. Laboratory and clinical tests must be conducted in accordance with applicable regulatory requirements in order to determine the safety and effectiveness for use of tubing in any particular application. ©2003 Saint-Gobain Performance Plastics Corporation This product is priced and sold by Packaged Length. At this time, this particular hose is not available \"by the foot\" through our site.\u003c\/p\u003e","brand":"Saint-Gobain","offers":[{"title":"Default Title","offer_id":45361538793634,"sku":"ACG42064 Saint Gobain","price":399.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0263\/2895\/7003\/files\/2475_9.png?v=1742648544"},{"product_id":"tygon-acg00046-5-8-i-d-x-7-8-o-d-x-1-8-wall-formulation-2475-50-package-length-high-purity-tubing","title":"ACG00046 Tygon® by Saint Gobain | 5\/8\" I.D. x 7\/8\" O.D x 1\/8\" Wall | Formulation 2475 | High Purity Tubing | 50' Package Length","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eSPECIFICATIONS\u003c\/p\u003e \n\u003cdiv class=\"table-responsive\"\u003e\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication:\u003c\/th\u003e\n\u003ctd\u003eSterile filling and Dispensing Systems, Diagnostic Equipment,  Nuclear Equipment, Laboratory Analytical Instrumentation,  Infusion Sets for Parenterals and Drugs, Cosmetic Production,  Food and Beverage Processing, Cell and Tissue Culture Transport\u003c\/td\u003e\n\u003cth\u003eSAE Rating:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOther Ratings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eTube:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReinforcement:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eCover:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Range:\u003c\/th\u003e\n\u003ctd\u003e-108 deg. F (-78 deg. C) - 125 deg. F (52 deg. C)\u003c\/td\u003e\n\u003cth\u003eCrimp Fittings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReusable Fittings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eSpecifications\u003c\/th\u003e\n\u003ctd\u003eFDA 21 CFR, USP Class VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLiterature:\u003c\/th\u003e\n\u003ctd colspan=\"3\"\u003e\u003ca href=\"\/http:\/\/emurdock.com\/tygontubing\/Tygon2475.pdf\"\u003eTygon® High Purity Tubing - Formulation 2475 (PDF)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"4\"\u003eOther Features:\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eExceptionally Low Absorption and Adsorption Compared to Silicone\u003c\/li\u003e\n\u003cli\u003eSmooth Inner Surface Inhibits Particulate Entrapment\u003c\/li\u003e\n\u003cli\u003eHighly Resistant to Aggressive Cleaners and Sanitizers\u003c\/li\u003e\n\u003cli\u003ePlasticizer Free\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cb\u003eWARNING: Tygon® High Purity Tubing - Formulation 2475 is not intended as an implant material.\u003c\/b\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"table-responsive\"\u003e\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eInside Diameter (in.)\u003c\/th\u003e\n\u003cth\u003eOutside Diameter (in.)\u003c\/th\u003e\n\u003cth\u003eWall Thickness (in.)\u003c\/th\u003e\n\u003cth\u003eMin. Bend Radius (in.)\u003c\/th\u003e\n\u003cth\u003eMax. Suggested Working Pressure at 180 deg. F (PSI)*\u003c\/th\u003e\n\u003cth\u003eVacuum Rating at 73 deg. F (in. Hg)\u003c\/th\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00003-1-16-I-D-x-3-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00003\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e60 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00007-1-8-I-D-x-1-4-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00007\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e45 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00012-3-16-I-D-x-5-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00012\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e5\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003ctd\u003e35 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00017-1-4-I-D-x-3-8-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00017\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e25 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00022-5-16-I-D-x-7-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00022\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/16\"\u003c\/td\u003e\n\u003ctd\u003e7\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1-3\/8\"\u003c\/td\u003e\n\u003ctd\u003e17 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00027-3-8-I-D-x-1-2-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00027\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1-5\/8\"\u003c\/td\u003e\n\u003ctd\u003e15 PSI\u003c\/td\u003e\n\u003ctd\u003e25.0 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00038-1-2-I-D-x-3-4-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00038\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2\"\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1-7\/8\"\u003c\/td\u003e\n\u003ctd\u003e20 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00046-5-8-I-D-x-7-8-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00046\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003ctd\u003e7\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e2-7\/8\"\u003c\/td\u003e\n\u003ctd\u003e17 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00053-3-4-I-D-x-1-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00053\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e16 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG42064-1-I-D-x-1-3-8-O-D-x-3-16-Wall-Formulation-2475-25-Package-Length-High-Purity-Tubing\"\u003eACG42064\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e1-3\/8\"\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e19 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e25ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e * Working pressures are calculated at a 1:5 ratio relative to burst pressure using ASTM D1599 Note: Every attempt has been taken to provide accurate detailed usable information online, however please consult Saint-Gobain Performance Plastics information documents for the most accurate and up to date data and specifics. \u003cb\u003eImportant!\u003c\/b\u003e It is the user's responsibility to ensure the suitability and safety of Saint-Gobain Performance Plastics tubing for all intended uses. Laboratory and clinical tests must be conducted in accordance with applicable regulatory requirements in order to determine the safety and effectiveness for use of tubing in any particular application. ©2003 Saint-Gobain Performance Plastics Corporation This product is priced and sold by Packaged Length. At this time, this particular hose is not available \"by the foot\" through our site.\u003c\/p\u003e","brand":"Saint-Gobain","offers":[{"title":"Default Title","offer_id":45361538826402,"sku":"ACG00046 Saint Gobain","price":421.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0263\/2895\/7003\/files\/2475_7.png?v=1742648547"},{"product_id":"tygon-acg00022-5-16-i-d-x-7-16-o-d-x-1-16-wall-formulation-2475-50-package-length-high-purity-tubing","title":"ACG00022 Tygon® by Saint Gobain | 5\/16\" I.D. x 7\/16\" O.D x 1\/16\" Wall | Formulation 2475 | High Purity Tubing | 50' Package Length","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eSPECIFICATIONS\u003c\/p\u003e \n\u003cdiv class=\"table-responsive\"\u003e\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication:\u003c\/th\u003e\n\u003ctd\u003eSterile filling and Dispensing Systems, Diagnostic Equipment,  Nuclear Equipment, Laboratory Analytical Instrumentation,  Infusion Sets for Parenterals and Drugs, Cosmetic Production,  Food and Beverage Processing, Cell and Tissue Culture Transport\u003c\/td\u003e\n\u003cth\u003eSAE Rating:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOther Ratings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eTube:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReinforcement:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eCover:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Range:\u003c\/th\u003e\n\u003ctd\u003e-108 deg. F (-78 deg. C) - 125 deg. F (52 deg. C)\u003c\/td\u003e\n\u003cth\u003eCrimp Fittings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReusable Fittings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eSpecifications\u003c\/th\u003e\n\u003ctd\u003eFDA 21 CFR, USP Class VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLiterature:\u003c\/th\u003e\n\u003ctd colspan=\"3\"\u003e\u003ca href=\"\/http:\/\/emurdock.com\/tygontubing\/Tygon2475.pdf\"\u003eTygon® High Purity Tubing - Formulation 2475 (PDF)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"4\"\u003eOther Features:\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eExceptionally Low Absorption and Adsorption Compared to Silicone\u003c\/li\u003e\n\u003cli\u003eSmooth Inner Surface Inhibits Particulate Entrapment\u003c\/li\u003e\n\u003cli\u003eHighly Resistant to Aggressive Cleaners and Sanitizers\u003c\/li\u003e\n\u003cli\u003ePlasticizer Free\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cb\u003eWARNING: Tygon® High Purity Tubing - Formulation 2475 is not intended as an implant material.\u003c\/b\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"table-responsive\"\u003e\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eInside Diameter (in.)\u003c\/th\u003e\n\u003cth\u003eOutside Diameter (in.)\u003c\/th\u003e\n\u003cth\u003eWall Thickness (in.)\u003c\/th\u003e\n\u003cth\u003eMin. Bend Radius (in.)\u003c\/th\u003e\n\u003cth\u003eMax. Suggested Working Pressure at 180 deg. F (PSI)*\u003c\/th\u003e\n\u003cth\u003eVacuum Rating at 73 deg. F (in. Hg)\u003c\/th\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00003-1-16-I-D-x-3-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00003\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e60 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00007-1-8-I-D-x-1-4-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00007\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e45 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00012-3-16-I-D-x-5-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00012\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e5\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003ctd\u003e35 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00017-1-4-I-D-x-3-8-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00017\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e25 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00022-5-16-I-D-x-7-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00022\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/16\"\u003c\/td\u003e\n\u003ctd\u003e7\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1-3\/8\"\u003c\/td\u003e\n\u003ctd\u003e17 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00027-3-8-I-D-x-1-2-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00027\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1-5\/8\"\u003c\/td\u003e\n\u003ctd\u003e15 PSI\u003c\/td\u003e\n\u003ctd\u003e25.0 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00038-1-2-I-D-x-3-4-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00038\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2\"\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1-7\/8\"\u003c\/td\u003e\n\u003ctd\u003e20 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00046-5-8-I-D-x-7-8-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00046\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003ctd\u003e7\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e2-7\/8\"\u003c\/td\u003e\n\u003ctd\u003e17 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00053-3-4-I-D-x-1-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00053\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e16 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG42064-1-I-D-x-1-3-8-O-D-x-3-16-Wall-Formulation-2475-25-Package-Length-High-Purity-Tubing\"\u003eACG42064\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e1-3\/8\"\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e19 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e25ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e * Working pressures are calculated at a 1:5 ratio relative to burst pressure using ASTM D1599 Note: Every attempt has been taken to provide accurate detailed usable information online, however please consult Saint-Gobain Performance Plastics information documents for the most accurate and up to date data and specifics. \u003cb\u003eImportant!\u003c\/b\u003e It is the user's responsibility to ensure the suitability and safety of Saint-Gobain Performance Plastics tubing for all intended uses. Laboratory and clinical tests must be conducted in accordance with applicable regulatory requirements in order to determine the safety and effectiveness for use of tubing in any particular application. ©2003 Saint-Gobain Performance Plastics Corporation This product is priced and sold by Packaged Length. At this time, this particular hose is not available \"by the foot\" through our site.\u003c\/p\u003e","brand":"Saint-Gobain","offers":[{"title":"Default Title","offer_id":45361540071586,"sku":"ACG00022 Saint Gobain","price":149.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0263\/2895\/7003\/files\/2475_4.png?v=1742648545"},{"product_id":"tygon-acg00003-1-16-i-d-x-3-16-o-d-x-1-16-wall-formulation-2475-50-package-length-high-purity-tubing","title":"ACG00003 Tygon® by Saint Gobain | 1\/16\" I.D. x 3\/16\" O.D x 1\/16\" Wall | Formulation 2475 | High Purity Tubing | 50' Package Length","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eSPECIFICATIONS\u003c\/p\u003e \n\u003cdiv class=\"table-responsive\"\u003e\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication:\u003c\/th\u003e\n\u003ctd\u003eSterile filling and Dispensing Systems, Diagnostic Equipment,  Nuclear Equipment, Laboratory Analytical Instrumentation,  Infusion Sets for Parenterals and Drugs, Cosmetic Production,  Food and Beverage Processing, Cell and Tissue Culture Transport\u003c\/td\u003e\n\u003cth\u003eSAE Rating:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOther Ratings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eTube:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReinforcement:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eCover:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Range:\u003c\/th\u003e\n\u003ctd\u003e-108 deg. F (-78 deg. C) - 125 deg. F (52 deg. C)\u003c\/td\u003e\n\u003cth\u003eCrimp Fittings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReusable Fittings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eSpecifications\u003c\/th\u003e\n\u003ctd\u003eFDA 21 CFR, USP Class VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLiterature:\u003c\/th\u003e\n\u003ctd colspan=\"3\"\u003e\u003ca href=\"\/http:\/\/emurdock.com\/tygontubing\/Tygon2475.pdf\"\u003eTygon® High Purity Tubing - Formulation 2475 (PDF)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"4\"\u003eOther Features:\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eExceptionally Low Absorption and Adsorption Compared to Silicone\u003c\/li\u003e\n\u003cli\u003eSmooth Inner Surface Inhibits Particulate Entrapment\u003c\/li\u003e\n\u003cli\u003eHighly Resistant to Aggressive Cleaners and Sanitizers\u003c\/li\u003e\n\u003cli\u003ePlasticizer Free\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cb\u003eWARNING: Tygon® High Purity Tubing - Formulation 2475 is not intended as an implant material.\u003c\/b\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"table-responsive\"\u003e\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eInside Diameter (in.)\u003c\/th\u003e\n\u003cth\u003eOutside Diameter (in.)\u003c\/th\u003e\n\u003cth\u003eWall Thickness (in.)\u003c\/th\u003e\n\u003cth\u003eMin. Bend Radius (in.)\u003c\/th\u003e\n\u003cth\u003eMax. Suggested Working Pressure at 180 deg. F (PSI)*\u003c\/th\u003e\n\u003cth\u003eVacuum Rating at 73 deg. F (in. Hg)\u003c\/th\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00003-1-16-I-D-x-3-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00003\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e60 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00007-1-8-I-D-x-1-4-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00007\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e45 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00012-3-16-I-D-x-5-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00012\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e5\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003ctd\u003e35 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00017-1-4-I-D-x-3-8-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00017\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e25 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00022-5-16-I-D-x-7-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00022\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/16\"\u003c\/td\u003e\n\u003ctd\u003e7\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1-3\/8\"\u003c\/td\u003e\n\u003ctd\u003e17 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00027-3-8-I-D-x-1-2-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00027\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1-5\/8\"\u003c\/td\u003e\n\u003ctd\u003e15 PSI\u003c\/td\u003e\n\u003ctd\u003e25.0 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00038-1-2-I-D-x-3-4-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00038\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2\"\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1-7\/8\"\u003c\/td\u003e\n\u003ctd\u003e20 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00046-5-8-I-D-x-7-8-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00046\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003ctd\u003e7\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e2-7\/8\"\u003c\/td\u003e\n\u003ctd\u003e17 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00053-3-4-I-D-x-1-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00053\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e16 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG42064-1-I-D-x-1-3-8-O-D-x-3-16-Wall-Formulation-2475-25-Package-Length-High-Purity-Tubing\"\u003eACG42064\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e1-3\/8\"\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e19 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e25ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e * Working pressures are calculated at a 1:5 ratio relative to burst pressure using ASTM D1599 Note: Every attempt has been taken to provide accurate detailed usable information online, however please consult Saint-Gobain Performance Plastics information documents for the most accurate and up to date data and specifics. \u003cb\u003eImportant!\u003c\/b\u003e It is the user's responsibility to ensure the suitability and safety of Saint-Gobain Performance Plastics tubing for all intended uses. Laboratory and clinical tests must be conducted in accordance with applicable regulatory requirements in order to determine the safety and effectiveness for use of tubing in any particular application. ©2003 Saint-Gobain Performance Plastics Corporation This product is priced and sold by Packaged Length. At this time, this particular hose is not available \"by the foot\" through our site.\u003c\/p\u003e","brand":"Saint-Gobain","offers":[{"title":"Default Title","offer_id":45361540956322,"sku":"ACG00003 Saint Gobain","price":74.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0263\/2895\/7003\/files\/2475.png?v=1742648571"},{"product_id":"tygon-acg00038-1-2-i-d-x-3-4-o-d-x-1-8-wall-formulation-2475-50-package-length-high-purity-tubing","title":"ACG00038 Tygon® by Saint Gobain | 1\/2\" I.D. x 3\/4\" O.D x 1\/8\" Wall | Formulation 2475 | High Purity Tubing | 50' Package Length","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eSPECIFICATIONS\u003c\/p\u003e \n\u003cdiv class=\"table-responsive\"\u003e\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication:\u003c\/th\u003e\n\u003ctd\u003eSterile filling and Dispensing Systems, Diagnostic Equipment,  Nuclear Equipment, Laboratory Analytical Instrumentation,  Infusion Sets for Parenterals and Drugs, Cosmetic Production,  Food and Beverage Processing, Cell and Tissue Culture Transport\u003c\/td\u003e\n\u003cth\u003eSAE Rating:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOther Ratings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eTube:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReinforcement:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eCover:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Range:\u003c\/th\u003e\n\u003ctd\u003e-108 deg. F (-78 deg. C) - 125 deg. F (52 deg. C)\u003c\/td\u003e\n\u003cth\u003eCrimp Fittings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReusable Fittings:\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003cth\u003eSpecifications\u003c\/th\u003e\n\u003ctd\u003eFDA 21 CFR, USP Class VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLiterature:\u003c\/th\u003e\n\u003ctd colspan=\"3\"\u003e\u003ca href=\"\/http:\/\/emurdock.com\/tygontubing\/Tygon2475.pdf\"\u003eTygon® High Purity Tubing - Formulation 2475 (PDF)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"4\"\u003eOther Features:\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eExceptionally Low Absorption and Adsorption Compared to Silicone\u003c\/li\u003e\n\u003cli\u003eSmooth Inner Surface Inhibits Particulate Entrapment\u003c\/li\u003e\n\u003cli\u003eHighly Resistant to Aggressive Cleaners and Sanitizers\u003c\/li\u003e\n\u003cli\u003ePlasticizer Free\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cb\u003eWARNING: Tygon® High Purity Tubing - Formulation 2475 is not intended as an implant material.\u003c\/b\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"table-responsive\"\u003e\u003ctable class=\"table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eInside Diameter (in.)\u003c\/th\u003e\n\u003cth\u003eOutside Diameter (in.)\u003c\/th\u003e\n\u003cth\u003eWall Thickness (in.)\u003c\/th\u003e\n\u003cth\u003eMin. Bend Radius (in.)\u003c\/th\u003e\n\u003cth\u003eMax. Suggested Working Pressure at 180 deg. F (PSI)*\u003c\/th\u003e\n\u003cth\u003eVacuum Rating at 73 deg. F (in. Hg)\u003c\/th\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00003-1-16-I-D-x-3-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00003\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e60 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00007-1-8-I-D-x-1-4-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00007\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e45 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00012-3-16-I-D-x-5-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00012\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e5\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003ctd\u003e35 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00017-1-4-I-D-x-3-8-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00017\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\"\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e25 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00022-5-16-I-D-x-7-16-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00022\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/16\"\u003c\/td\u003e\n\u003ctd\u003e7\/16\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1-3\/8\"\u003c\/td\u003e\n\u003ctd\u003e17 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00027-3-8-I-D-x-1-2-O-D-x-1-16-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00027\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/16\"\u003c\/td\u003e\n\u003ctd\u003e1-5\/8\"\u003c\/td\u003e\n\u003ctd\u003e15 PSI\u003c\/td\u003e\n\u003ctd\u003e25.0 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00038-1-2-I-D-x-3-4-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00038\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2\"\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e1-7\/8\"\u003c\/td\u003e\n\u003ctd\u003e20 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00046-5-8-I-D-x-7-8-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00046\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003ctd\u003e7\/8\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e2-7\/8\"\u003c\/td\u003e\n\u003ctd\u003e17 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG00053-3-4-I-D-x-1-O-D-x-1-8-Wall-Formulation-2475-50-Package-Length-High-Purity-Tubing\"\u003eACG00053\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e1\/8\"\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e16 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e50ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/Tygon-ACG42064-1-I-D-x-1-3-8-O-D-x-3-16-Wall-Formulation-2475-25-Package-Length-High-Purity-Tubing\"\u003eACG42064\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e1-3\/8\"\u003c\/td\u003e\n\u003ctd\u003e3\/16\"\u003c\/td\u003e\n\u003ctd\u003e3\"\u003c\/td\u003e\n\u003ctd\u003e19 PSI\u003c\/td\u003e\n\u003ctd\u003e29.9 in. Hg\u003c\/td\u003e\n\u003ctd\u003e25ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e * Working pressures are calculated at a 1:5 ratio relative to burst pressure using ASTM D1599 Note: Every attempt has been taken to provide accurate detailed usable information online, however please consult Saint-Gobain Performance Plastics information documents for the most accurate and up to date data and specifics. \u003cb\u003eImportant!\u003c\/b\u003e It is the user's responsibility to ensure the suitability and safety of Saint-Gobain Performance Plastics tubing for all intended uses. Laboratory and clinical tests must be conducted in accordance with applicable regulatory requirements in order to determine the safety and effectiveness for use of tubing in any particular application. ©2003 Saint-Gobain Performance Plastics Corporation This product is priced and sold by Packaged Length. At this time, this particular hose is not available \"by the foot\" through our site.\u003c\/p\u003e","brand":"Saint-Gobain","offers":[{"title":"Default Title","offer_id":45361541906594,"sku":"ACG00038 Saint Gobain","price":359.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0263\/2895\/7003\/files\/2475_6.png?v=1742648565"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0263\/2895\/7003\/collections\/2475_3_494x280_fdf20d1a-9d49-40db-a4a3-b6d9332e83d7.jpg?v=1739468984","url":"https:\/\/murdockindustrial.com\/collections\/high-purity-tubing.oembed","provider":"Murdock Industrial","version":"1.0","type":"link"}